- Introduction
- Parameters
- Dimensions
- Download
ST series damping rigid support legs have loose isolation requirement in good environment violation condition. Air mount isolator apply dual-chamber, damping hole techniques to get very low resonance frequency and effectively isolate high frequency vibration leading to plate deformation. Besides, basing on the load and self-weight to select BAT or SAT support, mount high-pressure gas source (air compressor or nitrogen bottles) and gas path control system(height control valves and pipes ) to achieve automatic balance of table system
PN | Structural | Natural frequency | Application |
RL | Damping rigid support legs | 5-10Hz | Industrial application Low environment vibration Low isolating demanding |
FL | Diaphragm air bag Dual-chamber Air damping hole | Vertical 1.0-1.8Hz Horizontal 1.2-2.0Hz | Small-sized breadboard Low load Small-sized precision instruments
|
HFL | Large diaphragm airbag Dual gas chamber Air damping hole | Vertical 1.0-2.0Hz Horizontal 1.2-2.2Hz | Large size bread board Heavy load Large-size experiment |